Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.866
Filtrar
1.
Radiol Clin North Am ; 62(3): 489-508, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553182

RESUMO

With the increasing prevalence of arrhythmias, the use of electrophysiology (EP) procedures has increased. Recent advancements in computed tomography (CT) technology have expanded its use in pre-assessments and post-assessments of EP procedures. CT provides high-resolution images, is noninvasive, and is widely available. This article highlights the strengths and weaknesses of cardiac CT in EP.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Humanos , Eletrofisiologia Cardíaca , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Tomografia Computadorizada por Raios X/métodos , Radiografia
2.
J Cardiovasc Electrophysiol ; 35(5): 916-928, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38439119

RESUMO

INTRODUCTION: Artificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12-lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospective, case-control study to evaluate the hypothesis that AI ECG mapping may reduce time to ablation, procedural duration, and fluoroscopy. MATERIALS AND METHODS: Cases in which system output was used were retrospectively enrolled according to IRB-approved protocols at each site. Matched control cases were enrolled in reverse chronological order beginning on the last day for which the technology was unavailable. Controls were matched based upon physician, institution, arrhythmia, and a predetermined complexity rating. Procedural metrics, fluoroscopy data, and clinical outcomes were assessed from time-stamped medical records. RESULTS: The study group consisted of 28 patients (age 65 ± 11 years, 46% female, left atrial dimension 4.1 ± 0.9 cm, LVEF 50 ± 18%) and was similar to 28 controls. The most common arrhythmia types were atrial fibrillation (n = 10), premature ventricular complexes (n = 8), and ventricular tachycardia (n = 6). Use of the system was associated with a 19.0% reduction in time to ablation (133 ± 48 vs. 165 ± 49 min, p = 0.02), a 22.6% reduction in procedure duration (233 ± 51 vs. 301 ± 83 min, p < 0.001), and a 43.7% reduction in fluoroscopy (18.7 ± 13.3 vs. 33.2 ± 18.0 min, p < 0.001) versus controls. At 6 months follow-up, arrhythmia-free survival was 73.5% in the study group and 63.3% in the control group (p = 0.56). CONCLUSION: Use of forward-solution AI ECG mapping is associated with reductions in time to first ablation, procedure duration, and fluoroscopy without an adverse impact on procedure outcomes or complications.


Assuntos
Potenciais de Ação , Arritmias Cardíacas , Inteligência Artificial , Ablação por Cateter , Valor Preditivo dos Testes , Tempo para o Tratamento , Humanos , Feminino , Masculino , Fluoroscopia , Estudos Retrospectivos , Idoso , Fatores de Tempo , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Resultado do Tratamento , Eletrocardiografia , Frequência Cardíaca , Duração da Cirurgia , Técnicas Eletrofisiológicas Cardíacas
5.
Circ Arrhythm Electrophysiol ; 17(3): e012278, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38344845

RESUMO

BACKGROUND: Electroporation is a promising nonthermal ablation method for cardiac arrhythmia treatment. Although initial clinical studies found electroporation pulsed-field ablation (PFA) both safe and efficacious, there are significant knowledge gaps concerning the mechanistic nature and electrophysiological consequences of cardiomyocyte electroporation, contributed by the paucity of suitable human in vitro models. Here, we aimed to establish and characterize a functional in vitro model based on human-induced pluripotent stem cells (hiPSCs)-derived cardiac tissue, and to study the fundamentals of cardiac PFA. METHODS: hiPSC-derived cardiomyocytes were seeded as circular cell sheets and subjected to different PFA protocols. Detailed optical mapping, cellular, and molecular characterizations were performed to study PFA mechanisms and electrophysiological outcomes. RESULTS: PFA generated electrically silenced lesions within the hiPSC-derived cardiac circular cell sheets, resulting in areas of conduction block. Both reversible and irreversible electroporation components were identified. Significant electroporation reversibility was documented within 5 to 15-minutes post-PFA. Irreversibly electroporated regions persisted at 24-hours post-PFA. Per single pulse, high-frequency PFA was less efficacious than standard (monophasic) PFA, whereas increasing pulse-number augmented lesion size and diminished reversible electroporation. PFA augmentation could also be achieved by increasing extracellular Ca2+ levels. Flow-cytometry experiments revealed that regulated cell death played an important role following PFA. Assessing for PFA antiarrhythmic properties, sustainable lines of conduction block could be generated using PFA, which could either terminate or isolate arrhythmic activity in the hiPSC-derived cardiac circular cell sheets. CONCLUSIONS: Cardiac electroporation may be studied using hiPSC-derived cardiac tissue, providing novel insights into PFA temporal and electrophysiological characteristics, facilitating electroporation protocol optimization, screening for potential PFA-sensitizers, and investigating the mechanistic nature of PFA antiarrhythmic properties.


Assuntos
Ablação por Cateter , Células-Tronco Pluripotentes Induzidas , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Arritmias Cardíacas/genética , Arritmias Cardíacas/cirurgia , Antiarrítmicos/uso terapêutico , Miócitos Cardíacos/metabolismo , Eletroporação , Ablação por Cateter/métodos
7.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38366154

RESUMO

AIMS: Common to adult electrophysiology studies (EPSs), intracardiac echocardiography (ICE) use in paediatric and congenital heart disease (CHD) EPS is limited. The purpose of this study was to assess the efficacy of ICE use and incidence of associated complications in paediatric and CHD EPS. METHODS AND RESULTS: This single-centre retrospective matched cohort study reviewed EPS between 2013 and 2022. Demographics, CHD type, and EPS data were collected. Intracardiac echocardiography cases were matched 1:1 to no ICE controls to assess differences in complications, ablation success, fluoroscopy exposure, procedure duration, and arrhythmia recurrence. Cases and controls with preceding EPS within 5 years were excluded. Intracardiac echocardiography cases without an appropriate match were excluded from comparative analyses but included in the descriptive cohort. We performed univariable and multivariable logistic regression to assess associations between variables and outcomes. A total of 335 EPS were reviewed, with ICE used in 196. The median age of ICE cases was 15 [interquartile range (IQR) 12-17; range 3-47] years, and median weight 57 [IQR 45-71; range 15-134] kg. There were no ICE-related acute or post-procedural complications. There were 139 ICE cases matched to no ICE controls. Baseline demographics and anthropometrics were similar between cases and controls. Fluoroscopy exposure (P = 0.02), procedure duration (P = 0.01), and arrhythmia recurrence (P = 0.01) were significantly lower in ICE cases. CONCLUSION: Intracardiac echocardiography in paediatric and CHD ablations is safe and reduces procedure duration, fluoroscopy exposure, and arrhythmia recurrence. However, not every arrhythmia substrate requires ICE use. Thoughtful selection will ensure the judicious and strategic application of ICE to enhance outcomes.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Adulto , Humanos , Criança , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ecocardiografia/métodos , Fluoroscopia , Ablação por Cateter/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia
8.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38367008

RESUMO

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Solução Salina/efeitos adversos , Vapor , Estudos Prospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Irrigação Terapêutica/efeitos adversos
10.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38363995

RESUMO

Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Fluxo de Trabalho , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos
12.
Herzschrittmacherther Elektrophysiol ; 35(Suppl 1): 102-109, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38407580

RESUMO

This article focuses on ventricular arrythmias without evidence for structural heart disease. There are many different reasons for this type of arrythmia and there is still a gap of knowledge. Starting with the first description of this disease, we present the diagnosis and management with medication, and finally catheter ablation procedures from the beginning to how it is currently treated and how it possibly will be treated in the near future.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia
13.
J Cardiovasc Electrophysiol ; 35(4): 625-638, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38174841

RESUMO

INTRODUCTION: The utility of ablation index (AI) to guide ventricular tachycardia (VT) ablation in patients with structural heart disease is unknown. The aim of this study was to assess procedural characteristics and clinical outcomes achieved using AI-guided strategy (target value 550) or conventional non-AI-guided parameters in patients undergoing scar-related VT ablation. METHODS: Consecutive patients (n = 103) undergoing initial VT ablation at a single center from 2017 to 2022 were evaluated. Patient groups were 1:1 propensity-matched for baseline characteristics. Single lesion characteristics for all 4707 lesions in the matched cohort (n = 74) were analyzed. The impact of ablation characteristics was assessed by linear regression and clinical outcomes were evaluated by Cox proportional hazard model. RESULTS: After propensity-matching, baseline characteristics were well-balanced between AI (n = 37) and non-AI (n = 37) groups. Lesion sets were similar (scar homogenization [41% vs. 27%; p = .34], scar dechanneling [19% vs. 8%; p = .18], core isolation [5% vs. 11%; p = .4], linear and elimination late potentials/local abnormal ventricular activities [35% vs. 44%; p = .48], epicardial mapping/ablation [11% vs. 14%; p = .73]). AI-guided strategy had 21% lower procedure duration (-47.27 min, 95% confidence interval [CI] [-81.613, -12.928]; p = .008), 49% lower radiofrequency time per lesion (-13.707 s, 95% CI [-17.86, -9.555]; p < .001), 21% lower volume of fluid administered (1664 cc [1127, 2209] vs. 2126 cc [1750, 2593]; p = .005). Total radiofrequency duration (-339 s [-24%], 95%CI [-776, 62]; p = .09) and steam pops (-155.6%, 95% CI [19.8%, -330.9%]; p = .08) were nonsignificantly lower in the AI group. Acute procedural success (95% vs. 89%; p = .7) and VT recurrence (0.97, 95% CI [0.42-2.2]; p = .93) were similar for both groups. Lesion analysis (n = 4707) demonstrated a plateau in the magnitude of impedance drops once reaching an AI of 550-600. CONCLUSION: In this pilot study, an AI-guided ablation strategy for scar-related VT resulted in shorter procedure time and average radiofrequency time per lesion with similar acute procedural and intermediate-term clinical outcomes to a non-AI-guided approach utilizing traditional ablation parameters.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Projetos Piloto , Cicatriz/diagnóstico , Cicatriz/etiologia , Cicatriz/cirurgia , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
15.
J Interv Card Electrophysiol ; 67(1): 147-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37311981

RESUMO

BACKGROUND: The lesion index (LSI) helps predict the lesion size and is widely used in ablation of various types of arrhythmias. However, the influence of the ablation settings on the lesion formation and incidence of steam pops under the same LSI value remains unclear. METHODS: Using a contact force (CF) sensing catheter (TactiCath™) in an ex vivo swine left ventricle model, RF lesions were created with a combination of various power steps (30 W, 40 W, 50 W) and CFs (10 g, 20 g, 30 g, 40 g, 50 g) under the same LSI values (5.2 and 7.0). The correlation between the lesion formation and ablation parameters was evaluated. RESULTS: Ninety RF lesions were created under a target LSI value of 5.2, and eighty-four were developed under a target LSI value of 7.0. In the LSI 5.2 group, the resultant lesion size widely varied according to the ablation power, and a multiple regression analysis indicated that the ablation energy delivered was the best predictor of the lesion formation. To create a lesion depth > 4 mm, an ablation energy of 393 J is the best cutoff value, suggesting a possibility that ablation energy may be used as a supplemental marker that better monitors the progress of the lesion formation in an LSI 5.2 ablation. In contrast, such inconsistency was not obvious in the LSI 7.0 group. Compared with 30 W, the 50-W ablation exhibited a higher incidence of steam pops in both the LSI 5.2 and 7.0 groups. CONCLUSIONS: The LSI-lesion size relationship was not necessarily consistent, especially for an LSI of 5.2. To avoid any unintentional, weak ablation, the ablation energy may be a useful supportive parameter (393 J as a cutoff value for a 4-mm depth) during ablation with an LSI around 5.2. Thanks to a prolonged ablation time, the LSI-lesion size relationship is consistent for an LSI of 7.0. However, it is accompanied by a high incidence of steam pops. Care should be given to the ablation settings even when the same LSI value is used.


Assuntos
Ablação por Cateter , Suínos , Animais , Vapor , Ventrículos do Coração/cirurgia , Arritmias Cardíacas/cirurgia
16.
Am Heart J ; 269: 15-24, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38042457

RESUMO

BACKGROUND AND OBJECTIVE: Patients with palpitations clinically suggestive of paroxysmal supraventricular tachycardia (PSVT) are often managed conservatively until ECG-documentation of the tachycardia, leading to high impact on life quality and healthcare resource utilization. We evaluated results of electrophysiological study (EPS), and ablation when appropriate, among these patients, with special focus on gender differences in management. METHODS: BELIEVE SVT is a European multicenter, retrospective registry in tertiary hospitals performing EPS in patients with palpitations, without ECG-documentation of tachycardia or preexcitation, and considered highly suggestive of PSVT by a cardiologist or cardiac electrophysiologist. We analyzed clinical characteristics, results of EPS and ablation, complications, and clinical outcomes during follow-up. RESULTS: Six-hundred eighty patients from 20 centers were included. EPS showed sustained tachycardia in 60.9% of patients, and substrate potentially enabling AVNRT in 14.7%. No major/permanent complications occurred. Minor/transient complications were reported in 0.84% of patients undergoing diagnostic-only EPS and 1.8% when followed by ablation. During a 3.4-year follow-up, 76.2% of patients remained free of palpitations recurrence. Ablation (OR: 0.34, P < .01) and male gender (OR: 0.58, P = .01) predicted no recurrence. Despite a higher female proportion among patients with recurrence, (77.2% vs 63.5% among those asymptomatic during follow-up, P < .01), 73% of women in this study reported no recurrence of palpitations after EPS. CONCLUSIONS: EPS and ablation are safe and effective in preventing recurrence of nondocumented palpitations clinically suggestive of PSVT. Despite a lower efficacy, this strategy is also highly effective among women and warrants no gender differences in management.


Assuntos
Ablação por Cateter , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Taquicardia Paroxística/diagnóstico , Arritmias Cardíacas/cirurgia , Sistema de Registros
19.
J Cardiovasc Electrophysiol ; 35(1): 206-213, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018417

RESUMO

Left ventricular assist device (LVAD) implantation is an established treatment for patients with advanced heart failure refractory to medical therapy. However, the incidence of ventricular arrhythmias (VAs) is high in this population, both in the acute and delayed phases after implantation. About one-third of patients implanted with an LVAD will experience sustained VAs, predisposing these patients to worse outcomes and complicating patient management. The combination of pre-existing myocardial substrate and complex electrical remodeling after LVAD implantation account for the high incidence of VAs observed in this population. LVAD patients presenting VAs refractory to antiarrhythmic therapy and catheter ablation procedures are not rare. In such patients, treatment options are extremely limited. Stereotactic body radiation therapy (SBRT) is a technique that delivers precise and high doses of radiation to highly defined targets, reducing exposure to adjacent normal tissue. Cardiac SBRT has recently emerged as a promising alternative with a growing number of case series reporting the effectiveness of the technique in reducing the VA burden in patients with arrhythmias refractory to conventional therapies. The safety profile of cardiac SBRT also appears favorable, even though the current clinical experience remains limited. The use of cardiac SBRT for the treatment of refractory VAs in patients implanted with an LVAD are even more scarce. This review summarizes the clinical experience of cardiac SBRT in LVAD patients and describes technical considerations related to the implementation of the SBRT procedure in the presence of an LVAD.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Radiocirurgia , Taquicardia Ventricular , Humanos , Radiocirurgia/efeitos adversos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Arritmias Cardíacas/cirurgia , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...